{"id":21209,"date":"2026-10-12T11:30:43","date_gmt":"2026-10-12T03:30:43","guid":{"rendered":"https:\/\/myliontech.com\/?p=21209"},"modified":"2026-10-12T11:30:43","modified_gmt":"2026-10-12T03:30:43","slug":"mini-ups-vs-ac-ups-uk-smart-buildings","status":"publish","type":"post","link":"https:\/\/myliontech.com\/en\/mini-ups-vs-ac-ups-uk-smart-buildings\/","title":{"rendered":"Mini UPS vs AC UPS for UK Smart Building Networks: A Selection Checklist"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"21209\" class=\"elementor elementor-21209\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-a6f6b06 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a6f6b06\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;ekit_has_onepagescroll_dot&quot;:&quot;yes&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2637c3f\" data-id=\"2637c3f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8ebd7c3 elementor-widget elementor-widget-text-editor\" data-id=\"8ebd7c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A <a href=\"https:\/\/myliontech.com\/en\/mini-ups\/\"><strong><u>Mini UPS<\/u><\/strong><\/a>\u00a0can provide local backup for compatible routers, ONTs and communication gateways in UK smart building projects. An <strong>AC UPS<\/strong>\u00a0is often more practical for equipment racks and grouped AC-powered devices.<\/p><p>The choice starts with three questions: which devices need backup, where they are installed, and what must remain connected during an outage.<\/p><p>For system integrators, the goal is to match backup power to the actual network layout, without adding unnecessary installation or maintenance work.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47f91d4 elementor-widget elementor-widget-heading\" data-id=\"47f91d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Why Smart Building Networks Need Local Backup<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-618cd8a elementor-widget elementor-widget-heading\" data-id=\"618cd8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">A Protected Network Room Does Not Cover Every Endpoint<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36ad090 elementor-widget elementor-widget-text-editor\" data-id=\"36ad090\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A building\u2019s central UPS may protect its main switches and servers while a gateway on another floor remains connected to an unprotected supply.<\/p><p>This gap can matter in retrofit projects, where new communication equipment is added outside the existing backup arrangement.<\/p><p>Local Mini UPS deployment can address selected gaps when the device and backup unit are compatible.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17f29ff elementor-widget elementor-widget-heading\" data-id=\"17f29ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Keep the Required Connection Available<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dbb7bee elementor-widget elementor-widget-text-editor\" data-id=\"dbb7bee\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Start with the service that must continue, such as tenant broadband or remote monitoring. Then identify the devices supporting it.<\/p><p>A router may also depend on an ONT and upstream switch. A monitoring gateway may depend on powered sensors and an external connection.<\/p><p><strong>Keeping one device powered does not establish end-to-end network availability.<\/strong><\/p><p>For additional context, read our <a href=\"https:\/\/myliontech.com\/en\/dc-backup-power-smart-building-network-devices-uk\/\"><u>UK smart building DC backup power guide<\/u><\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80a6302 elementor-widget elementor-widget-heading\" data-id=\"80a6302\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mini UPS vs AC UPS: A Quick Comparison<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac7dca7 elementor-widget elementor-widget-text-editor\" data-id=\"ac7dca7\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A Mini DC UPS supplies DC power directly to compatible equipment. An AC UPS supplies AC power to equipment or its existing adapters.<\/p><table><tbody><tr><td><p><strong><b>Project requirement<\/b><\/strong><\/p><\/td><td><p><strong><b>Mini UPS<\/b><\/strong><\/p><\/td><td><p><strong><b>AC UPS<\/b><\/strong><\/p><\/td><\/tr><tr><td><p>Individual router or gateway<\/p><\/td><td><p>Evaluate for compatible local DC backup<\/p><\/td><td><p>Can supply the existing AC adapter<\/p><\/td><\/tr><tr><td><p>Several devices in one rack<\/p><\/td><td><p>Check available outputs and combined load<\/p><\/td><td><p>Evaluate for grouped AC loads<\/p><\/td><\/tr><tr><td><p>Distributed endpoints<\/p><\/td><td><p>Provides backup at selected locations<\/p><\/td><td><p>Requires protected AC supplies at those locations<\/p><\/td><\/tr><tr><td><p>Restricted space<\/p><\/td><td><p>Check dimensions, cables and access<\/p><\/td><td><p>Allow space for the unit, outlets and adapters<\/p><\/td><\/tr><tr><td><p>Maintenance<\/p><\/td><td><p>Track and service multiple local units<\/p><\/td><td><p>Manage equipment around a shared backup source<\/p><\/td><\/tr><tr><td><p>Runtime<\/p><\/td><td><p>Test the actual device combination<\/p><\/td><td><p>Test the complete connected load<\/p><\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-20d6ba6 elementor-widget elementor-widget-heading\" data-id=\"20d6ba6\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Compare Performance by Model<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c44a057 elementor-widget elementor-widget-text-editor\" data-id=\"c44a057\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>AC UPS designs differ. Standby, line-interactive and online models do not have identical transfer or power-conditioning behaviour. Eaton\u2019s official guide explains these distinctions.<\/p><p>For either approach, assess the selected model with the equipment it will support.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41eee88 elementor-widget elementor-widget-heading\" data-id=\"41eee88\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">MYLION Mini UPS Options by Application<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be219f4 elementor-widget elementor-widget-heading\" data-id=\"be219f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">MU68W: Local Backup for Compatible 12V Devices<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f4faaa1 elementor-widget elementor-widget-text-editor\" data-id=\"f4faaa1\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/myliontech.com\/en\/mu68-12v-mini-ups-for-router\/\"><u>MYLION MU68W<\/u><\/a>\u00a0specification lists:<\/p><ul><li><strong>Output:<\/strong>12V DC, 2.5A continuous \/ 3A maximum.<\/li><li><strong>Battery capacity:<\/strong>4Wh.<\/li><li><strong>Dimensions:<\/strong>112 \u00d7 70 \u00d7 60mm.<\/li><\/ul><p><strong>Application to evaluate:<\/strong>\u00a0a compatible router, ONT or network endpoint installed away from the main cabinet.<\/p><p>In a tenant broadband installation, check whether both the router and ONT need backup. Include both loads and their connections in the assessment.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c4a011 elementor-widget elementor-widget-heading\" data-id=\"5c4a011\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">MU35W: More Current for Higher-Load Equipment<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1d51548 elementor-widget elementor-widget-text-editor\" data-id=\"1d51548\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/myliontech.com\/en\/mu35-12v-5a-dc-mini-ups\/\"><u>MYLION MU35W<\/u><\/a>\u00a0specification lists:<\/p><ul><li><strong>Output:<\/strong>12V DC, 4A continuous \/ 5A maximum.<\/li><li><strong>Battery capacity:<\/strong>6Wh.<\/li><li><strong>Dimensions:<\/strong>100 \u00d7 100 \u00d7 60mm.<\/li><\/ul><p><strong>Application to evaluate:<\/strong>\u00a0a compatible 12V gateway or router requiring more continuous current than MU68W supports.<\/p><p>For example, equipment genuinely requiring 3A continuously exceeds MU68W\u2019s listed continuous rating. MU35W is a candidate for further evaluation, subject to connector, startup-load and runtime checks.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ebc2ffa elementor-widget elementor-widget-heading\" data-id=\"ebc2ffa\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">MUJ46: Selected 12V and 5V Connections<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2079de4 elementor-widget elementor-widget-text-editor\" data-id=\"2079de4\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The <a href=\"https:\/\/myliontech.com\/en\/muj46-12v-dc-mini-ups\/\"><u>MYLION MUJ46<\/u><\/a>\u00a0page lists:<\/p><ul><li><strong>12V DC output.<\/strong><\/li><li><strong>USB-A 5V output.<\/strong><\/li><li><strong>USB-C 5V output.<\/strong><\/li><\/ul><p><strong>Application to evaluate:<\/strong>\u00a0a local installation containing a compatible 12V network device and a small 5V accessory.<\/p><p>Confirm the exact variant and combined-output limits before connecting several devices.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c54284 elementor-widget elementor-widget-image\" data-id=\"1c54284\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"558\" src=\"https:\/\/myliontech.com\/wp-content\/uploads\/2026\/10\/MYLION-MU68W-MU35W-MUJ46Mini-UPS-units-for-12V-continuous-local-backup.webp\" class=\"attachment-large size-large wp-image-21211\" alt=\"MYLION MU68W, MU35W, MUJ46Mini UPS units for 12V continuous local backup.\" srcset=\"https:\/\/myliontech.com\/wp-content\/uploads\/2026\/10\/MYLION-MU68W-MU35W-MUJ46Mini-UPS-units-for-12V-continuous-local-backup.webp 1000w, https:\/\/myliontech.com\/wp-content\/uploads\/2026\/10\/MYLION-MU68W-MU35W-MUJ46Mini-UPS-units-for-12V-continuous-local-backup-300x167.webp 300w, https:\/\/myliontech.com\/wp-content\/uploads\/2026\/10\/MYLION-MU68W-MU35W-MUJ46Mini-UPS-units-for-12V-continuous-local-backup-768x429.webp 768w, https:\/\/myliontech.com\/wp-content\/uploads\/2026\/10\/MYLION-MU68W-MU35W-MUJ46Mini-UPS-units-for-12V-continuous-local-backup-18x10.webp 18w, https:\/\/myliontech.com\/wp-content\/uploads\/2026\/10\/MYLION-MU68W-MU35W-MUJ46Mini-UPS-units-for-12V-continuous-local-backup-600x335.webp 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9fba315 elementor-widget elementor-widget-heading\" data-id=\"9fba315\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">When an AC UPS Makes More Sense<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c9ac1c6 elementor-widget elementor-widget-heading\" data-id=\"c9ac1c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Several Devices Share One Cabinet<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5fce124 elementor-widget elementor-widget-text-editor\" data-id=\"5fce124\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A network cabinet may contain switches, routers and other equipment with AC connections or existing adapters.<\/p><p>A shared AC UPS can be worth evaluating because it keeps backup equipment and maintenance access in one location.<\/p><p>Assess the full connected load, including downstream equipment powered through switches.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65d89d2 elementor-widget elementor-widget-heading\" data-id=\"65d89d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Central Backup Already Exists<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ab22d2 elementor-widget elementor-widget-text-editor\" data-id=\"1ab22d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Check the building\u2019s protected circuits and available UPS capacity before adding local units.<\/p><p>Extending a suitable existing arrangement may be more practical than introducing separate backup devices.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e8e7947 elementor-widget elementor-widget-heading\" data-id=\"e8e7947\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Different Locations Need Different Solutions<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5dfc14b elementor-widget elementor-widget-text-editor\" data-id=\"5dfc14b\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A building may use central backup for its network room and Mini UPS units for selected distributed endpoints.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f598446 elementor-widget elementor-widget-heading\" data-id=\"f598446\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Five Checks Before Choosing a Mini UPS<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc06de1 elementor-widget elementor-widget-heading\" data-id=\"fc06de1\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">1. Match the Connection<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-45d0fbc elementor-widget elementor-widget-text-editor\" data-id=\"45d0fbc\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Confirm voltage, connector dimensions and polarity.<\/p><p>A connector that fits physically may still be electrically unsuitable. Check the device documentation alongside the proposed UPS specification.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ffb54e2 elementor-widget elementor-widget-heading\" data-id=\"ffb54e2\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">2. Check Continuous and Startup Load<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cadb93f elementor-widget elementor-widget-text-editor\" data-id=\"cadb93f\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Use reliable device data or measurements.<\/p><p>The adapter\u2019s current rating describes its supply capability, rather than necessarily showing actual consumption. For shared backup, assess every connected device.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c71cb86 elementor-widget elementor-widget-heading\" data-id=\"c71cb86\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">3. Define the Backup Target<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65be9b2 elementor-widget elementor-widget-text-editor\" data-id=\"65be9b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Decide how long the required service must continue.<\/p><p>Test the actual equipment combination. Battery capacity alone cannot establish runtime under changing load and operating conditions.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c192137 elementor-widget elementor-widget-heading\" data-id=\"c192137\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">4. Check Space and Access<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cad77a7 elementor-widget elementor-widget-text-editor\" data-id=\"cad77a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Allow room for cables, secure connections and replacement.<\/p><p>Review temperature and installation requirements. A compact unit can still be difficult to maintain if placed above a ceiling or inside a restricted enclosure.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a33ed80 elementor-widget elementor-widget-heading\" data-id=\"a33ed80\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">5. Follow the Network Path<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-812c548 elementor-widget elementor-widget-text-editor\" data-id=\"812c548\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Identify upstream routers, switches and other dependencies.<\/p><p>For PoE devices, check the switch or injector supplying power. A standard DC output should not be assumed to provide compatible PoE.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b5bdd6c elementor-widget elementor-widget-heading\" data-id=\"b5bdd6c\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Compare the Complete Cost<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3becce7 elementor-widget elementor-widget-heading\" data-id=\"3becce7\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Include Installation Work<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3a325d5 elementor-widget elementor-widget-text-editor\" data-id=\"3a325d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Compare solutions protecting the same equipment for the same backup target.<\/p><p>Include units, cables, mounting, power distribution and installation labour. Purchase price is only one part of the decision.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-10a65d1 elementor-widget elementor-widget-heading\" data-id=\"10a65d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Consider Maintenance Access<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3a3119 elementor-widget elementor-widget-text-editor\" data-id=\"c3a3119\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Distributed Mini UPS units create more locations to inspect and track. Central backup concentrates access, but maintenance at a shared source can affect several devices.<\/p><p>Consider who will carry out replacements and what access each location requires.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e5e4b4 elementor-widget elementor-widget-heading\" data-id=\"3e5e4b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Standardise Approved Combinations<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4d19887 elementor-widget elementor-widget-text-editor\" data-id=\"4d19887\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Record the UPS model, supported device, connector arrangement and test result.<\/p><p>This helps maintenance teams identify suitable replacements. Recheck compatibility when network equipment changes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e1ceaaf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e1ceaaf\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;ekit_has_onepagescroll_dot&quot;:&quot;yes&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e903656\" data-id=\"e903656\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d48d7c5 elementor-widget elementor-widget-heading\" data-id=\"d48d7c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQ<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e33b7a elementor-widget elementor-widget-elementskit-faq\" data-id=\"2e33b7a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"elementskit-faq.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"ekit-wid-con\" >\n                <div class=\"elementskit-single-faq elementor-repeater-item-238c8b2\">\n            <div class=\"elementskit-faq-header\">\n                <h2 class=\"elementskit-faq-title\">Q1: Can a Mini UPS Replace an AC UPS?<\/h2>\n            <\/div>\n            <div class=\"elementskit-faq-body\">\n                Potentially, for selected compatible DC devices. It is not a universal replacement for rack-level or whole-building backup.            <\/div>\n        <\/div>\n                <div class=\"elementskit-single-faq elementor-repeater-item-5b4df90\">\n            <div class=\"elementskit-faq-header\">\n                <h2 class=\"elementskit-faq-title\">Q2: Can One Mini UPS Power a Router and an ONT?<\/h2>\n            <\/div>\n            <div class=\"elementskit-faq-body\">\n                Only when its outputs, connections and combined-load limits support both devices. Test the intended configuration before deployment.            <\/div>\n        <\/div>\n                <div class=\"elementskit-single-faq elementor-repeater-item-c048f47\">\n            <div class=\"elementskit-faq-header\">\n                <h2 class=\"elementskit-faq-title\">Q3: Which MYLION Model Should I Evaluate?<\/h2>\n            <\/div>\n            <div class=\"elementskit-faq-body\">\n                MU68W is a starting point for compatible lower-load 12V equipment. MU35W has a higher listed continuous current. MUJ46 offers selected 12V and 5V connections.\nFinal selection depends on the actual device requirements.            <\/div>\n        <\/div>\n                <div class=\"elementskit-single-faq elementor-repeater-item-9011f92\">\n            <div class=\"elementskit-faq-header\">\n                <h2 class=\"elementskit-faq-title\">Q4: Does a Mini UPS Guarantee Internet Availability?<\/h2>\n            <\/div>\n            <div class=\"elementskit-faq-body\">\n                No. It supports connected equipment; upstream network power and external service availability remain separate dependencies.            <\/div>\n        <\/div>\n                                <script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Q1: Can a Mini UPS Replace an AC UPS?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Potentially, for selected compatible DC devices. It is not a universal replacement for rack-level or whole-building backup.\"}},{\"@type\":\"Question\",\"name\":\"Q2: Can One Mini UPS Power a Router and an ONT?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Only when its outputs, connections and combined-load limits support both devices. Test the intended configuration before deployment.\"}},{\"@type\":\"Question\",\"name\":\"Q3: Which MYLION Model Should I Evaluate?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"MU68W is a starting point for compatible lower-load 12V equipment. MU35W has a higher listed continuous current. MUJ46 offers selected 12V and 5V connections.\\nFinal selection depends on the actual device requirements.\"}},{\"@type\":\"Question\",\"name\":\"Q4: Does a Mini UPS Guarantee Internet Availability?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. It supports connected equipment; upstream network power and external service availability remain separate dependencies.\"}}]}<\/script>\n                \n    <\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-495bc23 elementor-widget elementor-widget-heading\" data-id=\"495bc23\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e49124e elementor-widget elementor-widget-text-editor\" data-id=\"e49124e\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Choose a Mini UPS around a specific installation problem: an unprotected endpoint, insufficient current capability or a need for local backup.<\/p><p>Match the device requirements, test the required connection and plan maintenance access. This provides a stronger procurement basis than comparing product labels or battery capacity alone.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-871718d elementor-cta--skin-classic elementor-animated-content elementor-bg-transform elementor-bg-transform-zoom-in elementor-widget elementor-widget-call-to-action\" data-id=\"871718d\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"call-to-action.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-cta\">\n\t\t\t\t\t<div class=\"elementor-cta__bg-wrapper\">\n\t\t\t\t<div class=\"elementor-cta__bg elementor-bg\" style=\"background-image: url(https:\/\/myliontech.com\/wp-content\/uploads\/2026\/03\/section_17_bg-1-1024x480.webp);\" role=\"img\" aria-label=\"section_17_bg-1\"><\/div>\n\t\t\t\t<div class=\"elementor-cta__bg-overlay\"><\/div>\n\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-cta__content\">\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<h2 class=\"elementor-cta__title elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t\tPlanning Mini UPS backup for a UK smart building network? Contact MYLION to request a mini UPS project evaluation so we can discuss a suitable configuration.\t\t\t\t\t<\/h2>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-cta__button-wrapper elementor-cta__content-item elementor-content-item \">\n\t\t\t\t\t<a class=\"elementor-cta__button elementor-button elementor-size-\" href=\"https:\/\/myliontech.com\/en\/contact\/\" target=\"_blank\">\n\t\t\t\t\t\tContact US\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>A Mini UPS\u00a0can provide local backup for compatible routers, ONTs and communication gateways in UK smart building projects. An AC UPS\u00a0is often more practical for equipment racks and grouped AC-powered devices. The choice starts with three questions: which devices need backup, where they are installed, and what must remain connected during an outage. For system [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":21210,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_seopress_titles_title":"Mini UPS vs AC UPS for UK Smart Building Networks: A Selection Checklist","_seopress_titles_desc":"Compare Mini UPS and AC UPS solutions for UK smart building networks. Learn how to select the right local DC backup for routers, ONTs, and communication gateways.","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":"","content-type":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[35],"tags":[61,1313,1315,1314,1308],"class_list":["post-21209","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-12v-dc-ups","tag-24v-dc-backup-power","tag-backup-power-for-gateway","tag-backup-power-for-router","tag-dc-ups-for-network-devices"],"_links":{"self":[{"href":"https:\/\/myliontech.com\/en\/wp-json\/wp\/v2\/posts\/21209","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/myliontech.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/myliontech.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/myliontech.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/myliontech.com\/en\/wp-json\/wp\/v2\/comments?post=21209"}],"version-history":[{"count":4,"href":"https:\/\/myliontech.com\/en\/wp-json\/wp\/v2\/posts\/21209\/revisions"}],"predecessor-version":[{"id":21215,"href":"https:\/\/myliontech.com\/en\/wp-json\/wp\/v2\/posts\/21209\/revisions\/21215"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/myliontech.com\/en\/wp-json\/wp\/v2\/media\/21210"}],"wp:attachment":[{"href":"https:\/\/myliontech.com\/en\/wp-json\/wp\/v2\/media?parent=21209"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/myliontech.com\/en\/wp-json\/wp\/v2\/categories?post=21209"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/myliontech.com\/en\/wp-json\/wp\/v2\/tags?post=21209"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}