{"id":20025,"date":"2026-06-16T11:57:53","date_gmt":"2026-06-16T03:57:53","guid":{"rendered":"https:\/\/myliontech.com\/?p=20025"},"modified":"2026-11-17T07:02:49","modified_gmt":"2026-11-16T23:02:49","slug":"calculate-mini-ups-backup-time-for-a-routers-and-ont","status":"publish","type":"post","link":"https:\/\/myliontech.com\/es\/calculate-mini-ups-backup-time-for-a-routers-and-ont\/","title":{"rendered":"C\u00f3mo calcular el tiempo de respaldo de un mini UPS para un enrutador y un ONT"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"20025\" class=\"elementor elementor-20025\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-a6f6b06 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a6f6b06\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;ekit_has_onepagescroll_dot&quot;:&quot;yes&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2637c3f\" data-id=\"2637c3f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-877da2a elementor-widget elementor-widget-text-editor\" data-id=\"877da2a\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"mylion-geo-article\"><p>Para estimar cu\u00e1nto tiempo podr\u00e1 alimentar un mini SAI un router y un terminal de red \u00f3ptica (ONT), divida la energ\u00eda que puede suministrar en sus salidas de CC, en vatios-hora, entre la potencia media que consumen ambos dispositivos, en vatios. Ambas mediciones deben estar en el mismo lado de la etapa de conversi\u00f3n de energ\u00eda. Si el \u00fanico dato energ\u00e9tico disponible es la capacidad nominal de la bater\u00eda, el resultado es una estimaci\u00f3n hasta que se mida la energ\u00eda suministrada.<\/p><h2>Comience por los dispositivos<\/h2><p>Enumera todos los dispositivos que deben permanecer en l\u00ednea durante el corte de energ\u00eda. Un enrutador puede seguir transmitiendo Wi-Fi despu\u00e9s de que su ONT pierda energ\u00eda. Incluye el ONT aunque est\u00e9 en un gabinete diferente. Si la instalaci\u00f3n tambi\u00e9n alimenta un conmutador, incl\u00fayelo solo si el SAI propuesto realmente lo alimentar\u00e1.<\/p><p>Registre el voltaje, el conector y la polaridad requeridos para cada entrada de CC. Mida la potencia de entrada mientras el equipo maneja un tr\u00e1fico representativo. Registre el consumo en reposo por separado si la instalaci\u00f3n pasa mucho tiempo inactiva. Mantenga un registro aparte de la corriente de arranque. Un pico de corriente breve puede impedir que un dispositivo arranque incluso cuando hay suficiente energ\u00eda para varias horas de funcionamiento normal.<\/p><p>Un adaptador de 12 V y 2 A puede suministrar hasta 24 W a su potencia nominal. La etiqueta por s\u00ed sola no permite saber si el router conectado consume una media de 8 W o 18 W. Si el cliente solo env\u00eda una foto de la etiqueta, util\u00edcela para identificar los requisitos de alimentaci\u00f3n y solicite una lectura de carga antes de cotizar las horas. Un contador de pared incluye las p\u00e9rdidas del propio adaptador. Etiquete esa lectura como entrada de CA y evite mezclarla con la energ\u00eda medida en una toma de CC del SAI.<\/p><h2>Lee correctamente la cifra de energ\u00eda.<\/h2><p>Utilice la capacidad nominal en vatios-hora del paquete cuando est\u00e9 disponible. Para convertir amperios-hora a vatios-hora nominales, multiplique por el voltaje nominal de la bater\u00eda correspondiente a esa capacidad. Divida los miliamperios-hora entre 1000 para obtener los amperios-hora. Una salida regulada de 12 V no determina la base de voltaje de la cifra de capacidad impresa en otra parte de la carcasa.<\/p><p>Pregunte d\u00f3nde y c\u00f3mo se midi\u00f3 la energ\u00eda. Si un informe ya proporciona los vatios-hora de salida utilizables hasta el punto final de servicio acordado, divida esos vatios-hora directamente por la carga promedio correspondiente. Aplicar otro factor de eficiencia contabilizar\u00eda las p\u00e9rdidas dos veces. Si solo se dispone de los vatios-hora nominales de la bater\u00eda, indique la fracci\u00f3n estimada que llega a los dispositivos. Esta fracci\u00f3n puede depender de la carga, la temperatura, el corte y el estado de la bater\u00eda.<\/p><h2>Realizar una estimaci\u00f3n con dos dispositivos<\/h2><p>Las siguientes cifras describen una instalaci\u00f3n ilustrativa. Son estimaciones para comparar los requisitos energ\u00e9ticos y no representan ning\u00fan modelo ni prueba de MYLION.<\/p><div style=\"max-width: 100%; overflow-x: auto;\"><table><thead><tr><th scope=\"col\">Aporte<\/th><th scope=\"col\">Valor supuesto<\/th><th scope=\"col\">Resultado<\/th><\/tr><\/thead><tbody><tr><td>Enrutador en su entrada de CC<\/td><td>12 V \u00d7 0,75 A promedio<\/td><td>9 W<\/td><\/tr><tr><td>ONT en su entrada de CC<\/td><td>12 V \u00d7 0,25 A promedio<\/td><td>3 W<\/td><\/tr><tr><td>Carga media combinada<\/td><td>9 W + 3 W<\/td><td>12 W<\/td><\/tr><tr><td>Energ\u00eda nominal del paquete<\/td><td>60 Wh<\/td><td>60 Wh<\/td><\/tr><tr><td>Fracci\u00f3n supuesta entregada a los dispositivos<\/td><td>80%<\/td><td>48 Wh disponibles<\/td><\/tr><tr><td>Tiempo estimado a la carga supuesta<\/td><td>48 Wh \u00f7 12 W<\/td><td>4 horas<\/td><\/tr><\/tbody><\/table><\/div><p>Ahora bien, modifiquemos solo una entrada. Si el enrutador consume 4 W adicionales durante un tr\u00e1fico sostenido, la carga total asciende a 16 W. Con la misma energ\u00eda suministrada, la estimaci\u00f3n se reduce a tres horas. Este cambio es lo suficientemente significativo como para influir en la selecci\u00f3n del modelo. Por lo tanto, medir la carga durante los periodos de mayor actividad puede ser m\u00e1s \u00fatil que refinar un porcentaje de eficiencia supuesto.<\/p><p>Tambi\u00e9n se puede calcular a la inversa. Para un consumo de cinco horas a 12 W, los dispositivos necesitan 60 Wh en sus entradas. Con la misma fracci\u00f3n de suministro del chip 80%, el consumo nominal del paquete es de 75 Wh. Esta cifra establece un objetivo energ\u00e9tico. El voltaje de salida, los l\u00edmites de puertos simult\u00e1neos, el comportamiento al arrancar y el espacio disponible para la instalaci\u00f3n siguen determinando qu\u00e9 muestras merece la pena probar.<\/p><h2>Decida qu\u00e9 informaci\u00f3n puede incluir el departamento de compras en la solicitud de cotizaci\u00f3n.<\/h2><div style=\"max-width: 100%; overflow-x: auto;\"><table><thead><tr><th scope=\"col\">Lo que tienes<\/th><th scope=\"col\">Para qu\u00e9 puedes usarlo<\/th><th scope=\"col\">\u00bfQu\u00e9 solicitar a continuaci\u00f3n?<\/th><\/tr><\/thead><tbody><tr><td>Etiquetas del adaptador y una duraci\u00f3n objetivo<\/td><td>Identificar las posibles interfaces y un rango de potencia preliminar.<\/td><td>Lecturas de carga de CC para el par de dispositivos real<\/td><\/tr><tr><td>Carga medida y bater\u00eda nominal Wh<\/td><td>Comparar las estimaciones bajo los mismos supuestos establecidos.<\/td><td>Datos de energ\u00eda suministrada o una muestra para esa carga.<\/td><\/tr><tr><td>Resultado de muestra con los cables y dispositivos previstos.<\/td><td>Registrar el tiempo de ejecuci\u00f3n para esa configuraci\u00f3n.<\/td><td>Repita el procedimiento en las condiciones de mayor afluencia de clientes y a la temperatura acordada.<\/td><\/tr><tr><td>Una revisi\u00f3n diferente del ONT, del enrutador o del firmware<\/td><td>Identifique qu\u00e9 condiciones de prueba cambiaron<\/td><td>Revise la carga y repita las comprobaciones afectadas antes de la liberaci\u00f3n.<\/td><\/tr><\/tbody><\/table><\/div><h2>Preguntas que hacen los compradores<\/h2><p><strong>\u00bfPodemos usar un promedio para varios modelos de enrutadores?<\/strong> Agrupe las instalaciones solo cuando sus cargas y configuraciones de alimentaci\u00f3n respalden la misma suposici\u00f3n. Si se implementa un gateway de alto consumo en una minor\u00eda de sitios, calcule su consumo por separado. Un promedio de la flota puede ocultar una configuraci\u00f3n que no cumple con el requisito m\u00ednimo de servicio.<\/p><p><strong>\u00bfCu\u00e1ndo deber\u00eda detenerse el reloj?<\/strong> Acuerden qu\u00e9 evento es relevante para el operador. Si el ONT se desconecta mientras el router permanece encendido, el servicio de banda ancha ya ha finalizado. Registren por separado el tiempo de actividad del dispositivo y la disponibilidad del servicio al diagnosticar el resultado.<\/p><p><strong>\u00bfC\u00f3mo debemos tener en cuenta el envejecimiento?<\/strong> Indique al proveedor la vida \u00fatil prevista, la carga, el entorno operativo y el tiempo de funcionamiento requerido al final de dicho per\u00edodo. Solicite la justificaci\u00f3n de cualquier margen propuesto. Un porcentaje fijo copiado de otra instalaci\u00f3n puede ocultar diferencias de temperatura y ciclo de trabajo.<\/p><p>Para el piloto, utilice el <a href=\"https:\/\/myliontech.com\/es\/mini-ups-backup-time-isp-deployment\/\">Gu\u00eda de aceptaci\u00f3n del entorno de ejecuci\u00f3n del ISP<\/a>Para solicitar un <a href=\"https:\/\/myliontech.com\/es\/contact\/\">Revisi\u00f3n del proyecto Mini UPS<\/a>Env\u00ede a MYLION los modelos de los dispositivos, las cargas medidas, los detalles de conexi\u00f3n, las horas requeridas y la cantidad planificada para la prueba piloto. Identifique qu\u00e9 valores se midieron y cu\u00e1les son estimaciones para que la muestra pueda responder a las preguntas restantes.<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e1ceaaf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e1ceaaf\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;ekit_has_onepagescroll_dot&quot;:&quot;yes&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e903656\" data-id=\"e903656\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-871718d elementor-cta--skin-classic elementor-animated-content elementor-bg-transform elementor-bg-transform-zoom-in elementor-widget elementor-widget-call-to-action\" data-id=\"871718d\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;ekit_we_effect_on&quot;:&quot;none&quot;}\" data-widget_type=\"call-to-action.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-cta\">\n\t\t\t\t\t<div class=\"elementor-cta__bg-wrapper\">\n\t\t\t\t<div class=\"elementor-cta__bg elementor-bg\" style=\"background-image: url(https:\/\/myliontech.com\/wp-content\/uploads\/2026\/03\/section_17_bg-1-1024x480.webp);\" role=\"img\" aria-label=\"secci\u00f3n_17_bg-1\"><\/div>\n\t\t\t\t<div class=\"elementor-cta__bg-overlay\"><\/div>\n\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-cta__content\">\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<h2 class=\"elementor-cta__title elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t\t\u00bfNecesita ayuda para calcular el tiempo de respaldo de su ONT, enrutador, puerta de enlace o dispositivo CPE? \u00a1Contacte a MYLION!\t\t\t\t\t<\/h2>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-cta__button-wrapper elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t<a class=\"elementor-cta__button elementor-button elementor-size-\" href=\"https:\/\/myliontech.com\/es\/contact\/\" target=\"_blank\">\n\t\t\t\t\t\tCont\u00e1ctenos\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>To estimate how long a mini UPS will power a router and an optical network terminal (ONT), divide the energy it can deliver at its DC outputs, in watt-hours, by the average power the two devices draw, in watts. Both measurements belong on the same side of the power conversion stage. If the only energy [&hellip;]<\/p>","protected":false},"author":7,"featured_media":20033,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_seopress_titles_title":"How to Calculate Mini UPS Runtime for a Router and ONT","_seopress_titles_desc":"Estimate router and ONT backup time from measured DC load and watt-hours. Work through a two-device example and see which assumptions need a sample test.","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":"","content-type":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[35],"tags":[968,1179,82,1181,1180],"class_list":["post-20025","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-best-mini-ups-for-router-and-modem","tag-calculate-mini-ups-backup-time","tag-mylion-mini-ups","tag-ow-to-choose-a-mini-ups-for-wifi-router","tag-router-and-ont-power-consumption"],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/myliontech.com\/wp-content\/uploads\/2026\/06\/How-to-Calculate-Mini-UPS-Backup-Time-for-a-Routers-and-ONT.webp","_links":{"self":[{"href":"https:\/\/myliontech.com\/es\/wp-json\/wp\/v2\/posts\/20025","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/myliontech.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/myliontech.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/myliontech.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/myliontech.com\/es\/wp-json\/wp\/v2\/comments?post=20025"}],"version-history":[{"count":14,"href":"https:\/\/myliontech.com\/es\/wp-json\/wp\/v2\/posts\/20025\/revisions"}],"predecessor-version":[{"id":21897,"href":"https:\/\/myliontech.com\/es\/wp-json\/wp\/v2\/posts\/20025\/revisions\/21897"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/myliontech.com\/es\/wp-json\/wp\/v2\/media\/20033"}],"wp:attachment":[{"href":"https:\/\/myliontech.com\/es\/wp-json\/wp\/v2\/media?parent=20025"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/myliontech.com\/es\/wp-json\/wp\/v2\/categories?post=20025"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/myliontech.com\/es\/wp-json\/wp\/v2\/tags?post=20025"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}