What is Mini UPS?

mini ups

Definition of UPS:

Uninterruptible power supply (also known as UPS) is the uninterrupted provision of backup AC power for electrical load equipment in the event of abnormal power grids (such as power failure, undervoltage, interference or surge (surge current)). Equipment for the normal operation of electrical appliances. Under normal circumstances, uninterruptible power supplies are used to maintain the uninterrupted operation of key commercial equipment or precision instruments such as computers (especially servers) or switches, to prevent computer data loss, telephone communication network interruption or loss of control of the instrument.

The price of Mini UPS:

Mini up is a combination of multiple lithium cells in series and parallel, because if a single cell is a 12v lithium battery, the efficiency and life of the battery are not very good.

Mini up price estimation formula

Single lithium battery cell price x (3.6~3.7V*n)*m (number of cells connected in parallel) + protection board price + shell price + auxiliary material price + labor price

Generally, the voltage of a single batteria al litio cell is 3.6~3.7V, and its price will vary due to the different materials and processes used in the production of lithium battery manufacturers.

Mini UPS charger:

IL Mini-UPS charger is a charger specially used to charge batterie al litio. Lithium batteries have higher requirements for chargers and need protection circuits, so lithium battery chargers usually have higher control precision and can charge lithium batteries with constant current and voltage.

The lithium battery charger has over-voltage protection and temperature protection. The maximum charging time is limited to provide secondary protection for the batteria al litio. The floating charging method of the lithium battery charger can maximize the battery capacity.

Mini UPS protection board:

Mini up protection board, that is, a circuit board that plays a protective role. It is mainly composed of electronic circuits, which can accurately monitor the voltage of the cell and the current of the charging and discharging circuit at all times, and control the on and off of the current circuit in time.

The protection board can play the role of charging and discharging protection for the series and parallel battery packs, and at the same time can detect the overvoltage, overcurrent, overtemperature, undervoltage, and short circuit status of each single battery in the pacco batteria, prolong the battery life and avoid battery problems. Damaged by over-discharge. The protection board is an indispensable part of mini-up.

Precautions for the use of Mini UPS

1.Mini up should be kept at 50%-60% state of charge when stored for a long time and should be 2.recharged every 3 months, and charged and discharged every six months.

3.In the process of transportation, you should pay attention to moisture, moisture, and avoid squeezing, collision, etc., to avoid damage to the mini ups.

4.It is forbidden to use or place mini ups under high temperature (in the hot sun or in a very hot car), otherwise it may cause the batteria to overheat, catch fire or function failure, and shorten the life.

5.It is forbidden to store it in places with strong static electricity and strong magnetic fields, otherwise the battery safety protection device will be easily damaged and will bring hidden dangers of insecurity.

6.If the mini ups emits peculiar smell, heat, discoloration, deformation, or any abnormality occurs during use, storage, and charging, immediately remove the mini-up from the device or charger and stop using it.

Mylion 12V Mini UPS

Mini UPS type:

Note for charging Mini ups:

1.Charge in strict accordance with standard time and procedures.

2.Turn the switch to ON when charging, and check the status of the indicator light to see if the charging is effective.

3.Use the original charger, the original charger has strong supporting performance and moderate charging rate.

What should I do if the Mini UPS cannot be charged?

1.Whether the output parameters of the charger are normal, voltage, current, etc.;

2.Whether the charger circuit is normal and whether the connector is disconnected;

3.Whether the lithium battery is broken, you can test whether the open circuit voltage of the battery is normal.

If you have any questions,please fell free to contact MYLION Battery team,we will reply you ASAP !

Lascia un replay

Su di me

Mylion produce una serie di pacchi batteria, batterie al litio, batterie NiMH, batterie LiFe PO4, batterie ai polimeri di litio, power bank wireless, batterie RC Lipo, mini UPS ecc. Ampiamente utilizzati per prodotti elettrici portatili, robot intelligenti con intelligenza artificiale, rendono la vita delle persone comoda e intelligente.

Condividere:

Articoli recenti

Seguici

La storia di Mylion

Iscriviti alla nostra Newsletter

Grazie mille per averci fatto visita! Se hai una domanda o un commento, siamo qui e pronti ad aiutarti. Ti preghiamo di attendere 24 ore per una risposta durante i giorni feriali. Non condivideremo o distribuiremo mai le tue informazioni.
it_ITItaliano
Scorri verso l'alto