Over 11 Years Battery Manufacturer

Mylion 10kw 15kw ESS Small Size wall mount Home battery energy storage system solar power system

Mylion 10kw 15kw ESS Small Size wall mount Home battery energy storage system solar power system

Model No. ESS10-048005-30S60-145 ESS10US-048005-30U60-145 ESS15-048005-50S80-145
Grid Power Mode
Rated Input Voltage 220/230Vac 110/120Vac 220/230Vac
Input Voltage Range (170Vac~280Vac) ±2% (90Vac-280Vac)±2% (90Vac~140Vac) ±2% (170Vac~280Vac) ±2% (90Vac-280Vac)±2%
Frequency 50Hz/ 60Hz (自动侦测)
Frequency Range 47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short Circuit Protection Breaker
Efficiency >95%
Conversion Time (bypass and inverter) 10ms (typical value)
AC Backfeed Protection YES
Maximum Bypass Overload Current 30A 40A 40A
Inverter Mode
Output Voltage Waveform Pure Sine Wave
Rated Output Power 3300VA 3000VA 5000VA
Rated Output Power 3300W 3000W 5000W
Power Factor 1
Rated Output Voltage 230Vac 120Vac 230Vac
Output Voltage Error ±5%
Output Frequency Range 50Hz ± 0.3Hz   60Hz ± 0.3Hz
Efficiency >92% >91% >92%
Overload Protection (110%<load<125%) ±10%: report an error and turn off the output after 5 minutes;                      (125%<load<150%) ±10%: report an error and turn off the output after 10 seconds;                                     Load>150% ±10%: report an error and turn off the output after 5 seconds out; (102%<load<110%) ±10%: report error and wait for 5 minutes After closing the output;                            (110%<load<125%) ±10%: report error and wait for 10 seconds  After closing the output;                                Load>125% ±10%: report an error and turn off the output after 5 seconds out; (102%<load<125%) ±10%: report error and wait for 5 minutes After closing the output;                             (125%<load<150%) ±10%: report error and wait for 10 seconds After closing the output;                                       Load>150% ±10%: report an error and turn off the output after 5 seconds out;
Peak Power 6000VA 6000VA 10000VA
Loaded Motor Capacity 2HP 2HP 3HP
Output Short Circuit Protection Breaker
Bypass Breaker Specifications 30A 40A 40A
Battery Voltage Range 40.0Vdc~60Vdc ± 0.6Vdc (under voltage warning/shutdown voltage/over voltage warning/over voltage recovery…             LCD screen can be set)
Battery Type Lithium battery
Battery Power 5120Wh
Power Saving Mode Load≤50W
Grid Charge
Max Charge Current(Can be set) 60A 40A 60A
Charge Current Error ± 5Adc
Short Circuit Protection Circuit breakers and blown fuses
Breaker Specifications 40A
Overcharge Protection Alarm and turn off charging after 1 minute
Solar Charging
Maximum PV Open Circuit Voltage 145Vdc
PV Working Voltage Range 60-145Vdc
MPPT Voltage Range 60-115Vdc
Max Input Power 3400W 4400W
Solar Charge Current (configurable) 0-60A 0-80A
Charging Short Circuit Protection fuse
Wiring Protection Reverse polarity protection
Maximum Hybrid Charging Current (PV+AC)
Maximum Hybrid Charge Stream (configurable) 0-120A 0-100A 0-140A
Other Specifications
Working Temperature -15°C to 55°C
Storage Temperature -25°C ~ 60°C
Humidity Range 5% to 95%(three anti-paint protection)
Noise ≤60dB
Cooling Forced air cooling, adjustable wind speed
Communication USB/RS485/dry node control USB/RS485/WiFi/dry node control
Size (L*W*D) 845*530*200mm
Weight About 60kg

en_USEnglish