Mini UPS for ONT, ONU, Router & ISP Backup Projects

MYLION

Compare MYLION Mini UPS Models for Telecom and ISP Projects

Find the right backup solution for ONT, ONU, router, modem, FTTH, and modern network device applications.

Why Model Selection Matters

Use the comparison table to build a shortlist, then confirm each model against the complete device setup. Check the required input voltage, connector dimensions and polarity, and confirm whether the stated output rating is continuous or peak. For an ONT plus router, assess the combined load and output connections. Battery capacity or a runtime figure alone does not establish suitability for your devices. Validate the selected configuration under its actual load and power-loss recovery conditions before rollout.

For device selection checks, see the ONT/ONU backup guide. For pilot planning and test records, see the ISP pilot checklist.

Which Model Fits Which Need?

Mini UPS Model Comparison

Read capacity, output and runtime separately

Use this table to build a shortlist, not to assume compatibility. Battery Wh describes nominal energy. Output voltage, current and power limits describe the load that a configuration may supply. A runtime figure is comparable only when its device load, operating conditions and measurement method are stated.

For example, 44.4Wh divided by a constant 12W load is 3.7 hours before losses; 75.6Wh divided by 18W is 4.2 hours before losses. These are calculations, not measured or guaranteed backup times. Confirm the proposed model configuration and test it with the intended devices.

Understand runtime estimates · Check device compatibility · Plan an ISP pilot

ModelBattery CapacityMax OutputInterfaceRuntime Basis / Test ConditionsBattery TypeRecommended Application
ML1202AC25.6Wh12V / 2AAC input + DC outputLoad-specific runtime must be confirmed for the proposed configuration.LiFePO4Dual-device backup for ONT + router, modem + router, and low-power broadband CPE where AC input convenience is required.
MUC8592WhUSB-C PD 65W
5V / 9V / 12V / 15V  3A
20V  3.25A
USB-C PD 65W Input / OutputLoad-specific runtime must be confirmed for the proposed configuration.Lithium ionUSB-C PD backup for WiFi 6/7 routers, advanced CPE, 5V/9V/12V/15V/20V PD devices, and selected fixed-voltage USB-C network equipment.
MU35W75.6Wh12V / 5ADC 12VLoad-specific runtime must be confirmed for the proposed configuration.Lithium ionHigh-power 12V backup for broadband gateways, CPE, LTE/5G routers, ONT + router systems, and ISP customer-premises backup projects.
MU26W18.72Wh12V / 3ADC 12VLoad-specific runtime must be confirmed for the proposed configuration.Lithium ionCompact 12V backup for low-power ONT, ONU, modem, router, VoIP adapter, and basic FTTH subscriber-side devices.
MU48W29.6Wh12V / 3ADC 12VLoad-specific runtime must be confirmed for the proposed configuration.Lithium ion12V backup for routers, modems, small switches, VoIP gateways, CCTV terminals, and small office network devices.
MU68W44.4Wh12V / 3ADC 12V12W load: theoretical upper limit 3.7 hours (44.4Wh / 12W), before losses; not measured or guaranteed. Actual runtime requires testing.Lithium ionStandard 12V broadband backup for ONT, ONU, router, modem, CPE, and mainstream ISP / telecom subscriber-side deployment.
MUJ4637.44Wh12V / 2A             5V / 3ADC 12V+USB-A / USB-C 5VLoad-specific runtime must be confirmed for the proposed configuration.Lithium ion12V + USB 5V backup for router + USB-powered accessory, modem + USB device, WiFi router + mobile terminal, and mixed-output backup scenarios.
MU248102.4Wh24V / 3A          48V / 1ADC 24V / 48VLoad-specific runtime must be confirmed for the proposed configuration.LiFePO424V / 48V backup for wireless CPE, outdoor bridge, radio equipment, small telecom terminals, and non-standard DC network devices.

Recommended by Customer Type

ISP / Telecom Operator

System Integrator

Distributor

FTTH Project Buyer

How to Select the Right Model

MYLION can help evaluate these factors and recommend the most suitable model. Before choosing a Mini UPS model, please confirm:

Why MYLION Product Line

MYLION’s Mini UPS range is not random. Each model is designed for a specific backup need:

Not Sure Which Model Fits Your Device?

Different devices require different backup solutions. If you are not sure which model is right for your project, MYLION can help based on your actual application.

mylion banner

Please share:

Frequently Asked Questions

Select the first sample from the device requirements and the documented configuration. Confirm voltage, connectors, load and target runtime before deciding which model to test.

Choose MU35 when your device requires higher current or when a standard 12V 3A model may not be sufficient.

Evaluate the proposed MUJ46 configuration against the installation space, cable route and required outputs; verify the fit in the intended setup.

Not necessarily. MUC85 is more suitable for compatible USB-C / PD applications, not for every standard DC backup project.

Yes. Please share your device details, power requirements, and target backup time.

Hello Dears! we will help

Not Sure Which Mini UPS Model Fits Your Project?

Send us your device model, voltage, current, and backup time target. MYLION will recommend the most suitable solution for your telecom or ISP project.

en_USEnglish